Human Cyclophilin / Cyclophilin A (CyPA) Elisa Kit

Instructions for Human Cyclophilin / Cyclophilin A (CyPA) Elisa Kit Human Cyclophilin / Cyclophilin A (CyPA) Elisa Kit is for research use only. Detection range: 96T 0.6ng / ml-16ng / ml Purpose: This kit is used to determine the content of cyclophilin / cyclophilin A (CyPA) in human serum, plasma and related liquid samples. Experimental principle: This kit uses the double antibody sandwich method to determine the level of human cyclophilin / cyclophilin A (CyPA) in the specimen. Microporous plates were coated with purified human cyclophilin / cyclophilin A (CyPA) antibody to prepare solid-phase antibodies, and cyclophilin / cyclophilin A (CyPA) was added to the microwells coated with monoclonal antibody in sequence. It is then combined with the HRP-labeled cyclophilin / cyclophilin A (CyPA) antibody to form an antibody-antigen-enzyme-labeled antibody complex. After thorough washing, the substrate TMB is added for color development. TMB is converted into blue under the catalysis of HRP enzyme, and into the final yellow under the action of acid. The color depth is positively correlated with cyclophilin / cyclophilin A (CyPA) in the sample. The absorbance (OD value) was measured with a microplate reader at a wavelength of 450 nm, and the concentration of human cyclophilin / cyclophilin A (CyPA) in the sample was calculated by a standard curve. Composition of Human Cyclophilin / Cyclophilin A (CyPA) Elisa kit: 1.30 times concentrated washing solution 20ml × 1 bottle 7 stop solution 6ml × 1 bottle; 2. enzyme labeling reagent 6ml × 1 bottle 8 standard (32ng / ml) ) 0.5ml × 1 bottle; 3. Enzyme label coated plate 12 wells × 8 strips 9 standard dilutions 1.5ml × 1 bottles; 4. sample dilutions 6ml × 1 bottles 10 instructions 1 part; 5. Developer A 6ml × 1 bottle with 11 sealing plates and 2 films; 6. Developer B solution 6ml × 1 / bottle 12 with 1 sealed bag; Specimen requirements: 1. Extract the specimens as soon as possible after collection, and the extraction should be carried out according to relevant literature. Experiments should be conducted as soon as possible. If the test cannot be performed immediately, the specimen can be stored at -20 ° C, but repeated freezing and thawing should be avoided. 2. The sample containing NaN3 cannot be detected because NaN3 inhibits the activity of horseradish peroxidase (HRP). Operation steps: 1. Dilution of standard product: This kit provides one original standard product. The user can perform dilution in a small test tube according to the following chart. 16ng / ml No. 5 standard 150μl original standard added 150μl standard dilution; 8ng / ml No. 4 standard 150μl No. 5 standard added 150μl standard dilution; 4ng / ml No. 3 standard 150μl 4 Add 150μl standard dilution to No. 1 standard; 150μl standard No. 2 to 2ng / ml No. 2 standard add 150μl standard dilution; 150μl No. 2 to 1ng / ml standard No. 1 add 150μl standard dilution 2. Adding samples: set up blank wells (the blank control wells do not add samples and enzyme reagents, the rest of the steps are the same), standard wells, sample wells to be tested. Add 50μl of the standard on the enzyme-coated plate accurately, add 40μl of sample diluent to the sample well, and then add 10μl of the sample to be tested (the final dilution of the sample is 5 times). Add the sample and add the sample to the bottom of the well of the microplate, try not to touch the wall of the well, shake gently to mix. 3. Incubation: seal the plate with a sealing film and incubate at 37 ° C for 30 minutes. 4. Mixing solution: Dilute the 30-fold concentrated washing solution with distilled water 30-fold. 5. Wash: Carefully remove the sealing film, discard the liquid, spin dry, fill each well with the washing solution, and let it sit for 30 seconds , Repeat this 5 times, pat dry. 6. Add enzyme: add 50μl of enzyme label reagent to each well, except blank well. 7. Incubation: The operation is the same as 3. 8. Washing: The operation is the same as 5. 9. Color development: add 50μl of developer A to each well, then add 50μl of developer B, mix gently, and develop color at 37 ℃ in the dark 15 minutes. 10. Stop: add 50 μl of stop solution to each well to stop the reaction (at this time, the blue turns to yellow). 11. Determination: Measure the absorbance (OD value) of each well in sequence with the blank air conditioner at zero and 450 nm wavelength. The measurement should be carried out within 15 minutes after adding the stop solution. Summary of operating procedures: calculation: take the concentration of the standard as the abscissa and the OD as the ordinate, draw a standard curve on the graph paper, and find the corresponding concentration from the standard curve according to the OD value of the sample; then multiply by the dilution factor; Or use the standard concentration and OD value to calculate the linear regression equation of the standard curve, substitute the OD value of the sample into the equation, calculate the sample concentration, and then multiply it by the dilution factor to obtain the actual concentration of the sample. Note: 1. The kit should be taken out of the refrigerated environment and should be equilibrated at room temperature for 15-30 minutes before use. If the enzyme label coated plate is not used up after opening, the strip should be stored in a sealed bag. 2. Crystals may be precipitated in the concentrated washing liquid, which can be heated and dissolved in the water bath during dilution, and the results will not be affected during washing. 3. The sample adder should be used in each step of sample addition, and its accuracy should be regularly checked to avoid test errors. It is best to control the sampling time within 5 minutes. If there are many specimens, it is recommended to use a volley gun to add samples. 4. Please make a standard curve at the same time of each measurement, it is best to make a double hole. If the content of the substance to be tested in the specimen is too high (the OD value of the sample is greater than the OD value of the first well of the standard well), please dilute it with a certain multiple of the sample diluent (n times) before measuring, and finally multiply the total dilution when calculating Multiple (× n × 5). 5. The sealing film is limited to one-time use to avoid cross contamination. 6. Please keep the substrate away from light. 7. Strictly follow the instructions, and the test results must be determined based on the reading of the microplate reader. 8. All samples, washing liquid and various wastes should be treated as infectious agents. 9. The components of different batches of this reagent shall not be mixed. 10. If there is any difference with the English manual, the English manual shall prevail. Storage conditions and expiration date 1. Kit storage: 2-8 ℃. 2. Validity: 6 months

Double PP tapes to fix the diaper to body: 

they can be refastened for many times 

3D leak prevention channels to ensure zero leakage, wearer can move freely 

The rear side of absorption core is widened to improve backward leakage trouble 

Super absorption system to hold the fluid quickly 

'8' shape absorption core, more comfortable 

Premium disposable nappies for adults


Super lock of water, prevent water back:Soft hydrophilic non-woven top-sheet with two absornency layers, absorb water by every part and super lock, keep comfortable and soft in every moment


Super breathable, keep bedsore away: Waterproof breathable backsheet, which is composed of nanoscale breathable micro holes, efficient discharge heat and effectively prevent bedsore


Super leakproof, safe conveniently:Dual stereo soft elastic leakproof design keep people more safe to use Diapers, which reduce the unnecessary washing and nursing work


Double flat magic tapes to fix the diaper well to body: Double widen magic tapes on both sides, the strong stick power to fis diaper on body well


Super absorption, lasting dry: The super absorption core is constituted by imported fluff pulp and SAP, which can lock urine promptly and keep the strong absorption capacity for long time



Elastic PU form waistband: Unique stretchy waistband is softly fixed around by belly and flesible to body, it is more comfortable to wearer

Adult Diapers

Adult Diaper,Adult Pull Ups,Adult Diapers,Disposable Adult Diapers

Zhejiang Youquan Care Products Technology Co., Ltd. , https://www.youquancare.com

Posted on