The meaning of the parameters of the air-opening specification model How to choose the air-opening specification model

At present, there are two major categories of air-to-air applications, one is home improvement and the other is engineering. In fact, in our daily life or work place, we can see the air switch , and often can be used, but many people lack some professional knowledge when the device is open , and do not know when they buy the air switch. Which model to buy, for this reason, the editor will come to talk to you today about what the meaning of the parameters of the open specifications is. At the same time, I have prepared some methods for purchasing the open specifications .

If it were not for home decoration, you might not understand this product, although small objects also play a decisive role. The air switch is the main hub of the home power supply. Of course, its quality problems cannot be ignored. Try to choose products with guaranteed quality when buying.

The meaning of the model parameters

DZ47-60 C60

400V--4000A

DZ: Small air circuit breaker 47: Design serial number

63: the largest model of this specification C: for general lighting 40: model-A

220V / 380V: rated voltage 50HZ: rated frequency

6000: rated operating short-circuit breaking capacity-A

At present, households use the DZ series of air switches, the following models / specifications are common: C16, C25, C32, C40, C60, C80, C100, C120 and other specifications, where C represents the tripping current, that is, the tripping current, such as C16 means the trip The current is 16 amps. Generally, 2500W electric water faucet needs to use C16, and 7500W and 8500W water heaters need to use C40 air switch.

Name: C65N Model: D10 3P

C: Schneider's design serial number, miniature circuit breaker

N: breaking capacity, 6KA

D: Tripping level, 10-14 times, used for protection of high inrush current such as motor

P: series

Air switch DZ10-250 Ie = 200 where DZ stands for “automatic”, 10 is its design serial number, 250 is its frame rating, Ie = 200 means its rated current is 200A

Air switch DZ10-100 / 330 Ie = 60A, where 100 of 100/330 means it is a 100 amp shell. 330 is a circuit breaker for power distribution that represents a three-phase double trip.

ABB does not have a blank opening at the beginning of C. In fact, it does not matter what letter starts, because DS260-C (breaking capacity is 6KA) only represents the model of ABB electromagnetic leakage switch. The C65N only represents a Schneider breaker with a breaking capacity of 6KA (without leakage, an additional leakage protection accessory can also be added)

Open specifications :

C65N 1P-: C1A C2A C4A C6A C10A C16A C20A C25A C32A C40A C50A C63A C65N 2P-: C1A C2A C4A C6A C10A C16A C20A C25A C32A C40A C20A C32A C20A -: C1A C2A C4A C6A C10A C16A C20A C25A C32A C40A C50A C63A C65N 1P-: D1A D2A D4A D6A D10A D16A D20A D25A D32A D40A D50A D63A C65N 2P-: D1A D2A D4A D6A D2A D4A D4A D2A D4A D2A D4A D2A D4A D6A D1A D2A D4A D6A D10A D16A D20A D25A D32A D40A D50A D63A

The model increase is generally 6, 10, 16, 20, 25, 32, 40, 50, 63, 80, 100, 125, 150, 225, 400.

D stands for power and C stands for lighting.

At present, households use DZ series air switches (small circuit breakers with leakage protection). The following models / specifications are common: C16, C25, C32, C40, C60, C80, C100, C120 and other specifications, where C represents the trip current , That is, the take-off current, for example, C32 indicates that the take-off current is 32 amps. Generally, C32 is used to install 6500W water heaters, and C40 is required to install 7500W and 8500W water heaters. Common models in industry are: DW and DZ types for power circuits are divided into 20, 32, 50, 63, 80, 100, 125, 160, 250, 400, 600, 800, 1000 ... (Unit A).

The rated current of open circuit breaker is several amperes to several hundred amperes, such as 10 amperes and 600 amperes, but the maximum current of ordinary DZ47-63 series is 63 amperes, divided into 5 10 16 (15) 20 25 32 (30) 40 50 60 (63) seems to have 3A and 2.5A.

How to choose the model of open circuit

The MCB is used as a main power protection switch or a branch line protection switch in household power supply. When a short circuit or overload occurs in a residential circuit or household appliance, it can automatically trip and cut off the power supply, thereby effectively protecting these devices from damage or preventing accidents from expanding; households generally use two-pole (ie 2P) air switches for total power protection. Use single pole (1P) as branch protection; if the rated current of the air switch is too small, the air switch is likely to trip frequently, causing unnecessary power outages. If the selection is too large, the expected protection effect will not be achieved, so home improvement Air switch, it is important to choose the rated capacity current correctly. General small air switch specifications are mainly divided by rated current 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A, 100A, etc. So how does the general family choose or verify the total value of the total load current?

1. First calculate the value of each branch current

Pure resistive loads, such as light bulbs, electric heaters, etc., can be obtained by directly dividing the indicated power by the voltage. The formula I = power / 220v; for example, 20w bulb, the branch current I = 20W / 220 = 0.09A. Electric fans, electric irons, electric blankets, electric water heaters, electric heaters, rice cookers, electric frying pans, vacuum cleaners, air conditioners, etc. are resistive loads.

The calculation of inductive loads, such as fluorescent lamps, TV sets, washing machines, etc. is a little complicated, and the power consumption must be considered. The specific calculation must also consider the power factor. For easy estimation, the author gives a simple calculation method, that is, general inductive loads Note that the calculated power of the load can be doubled. For example, the branch current of a 20W fluorescent lamp I = 20W / 220v = 0.09A, the doubled value is 0.09A * 2 = 0.18A (more than the calculated value of 0.15A, 0.03A more).

2. The total load current is the sum of the branch currents

Knowing the branch current and the total current, you can choose the specifications of the branch air switch and the main brake air switch, the main fuse, the main electricity meter, and the wires of each branch, or verify whether the specifications of these designed electrical components meet the safety requirements.

3. In order to ensure safety and reliability, the rated working current of electrical components should generally be greater than 2 times the maximum load current required

In addition, when designing and selecting electrical components, it is also necessary to consider the possibility of an increase in the electrical load in the future, leaving room for future demand.

About open space above specification model parameters mean and how to choose the open space of standard models for everyone brief introduction here, I hope the above information to be helpful. Only when you understand the specifications and parameters of the air switch can you buy a suitable one. In addition, if there is a power failure or trip in daily life, the air circuit breaker must be checked first. Finally, thank you all for reading.

What, the decoration still uses his own money? ! The Qi family is decorated in installments, with an ultra-low annual interest rate of 3.55% and a maximum loan of 1 million. Apply now to enjoy the discount

If you are interested in brand cooperation, content cooperation, and advertising of this website, please send an email to :.

switch

Single Dome Operating Light

KDLED500 (2)

LED-Q65


Germany imported beads

Imported French lens

mould Die-casting Eight edge type Revolving arm

Optional emergency power supply≥3 hours


The main features:

1)Ideal cold light effects

Using the new LED cold light source, ensure energy saving and environmental protection and long service life up to 80,000hours and more.

The temperature increase of surgeon`s head below 1℃. LED do not engender infrared ray and ultraviolet radiation, without the temperature

rise and tissue damage caused by halogen shadowless light, also it can accelerate the wound healing after surgery, and without Radiation pollution.

With color temperature constant and soft, LED is very close to the sunshine.

1) Excellent shadowless effect

Lamp with the most scientific radian and Multi point light source design, ensure better uniform illuminance. When the lamps are partially occluded,

also can achieve perfect shadowless effect.Lamp panel radius of gyration ≥182cm, the lamp can be pulled to vertical floor, convenient to any angle illumination.

2) Excellent deep lighting

It is based on modularize method by Computer Aided Design, focused to irradiating with more beams of LED. It produces the deep lighting which beams

more than 1200cm,the illumination of center up to 180,000Lux or more, and offer the color temperature that can be adjusted from 3700K to 5000K which

is close to sunshine. Absolutely, it really reflects the color of human tissue and satisfied by all kinds of operating light needs.

3) Advanced control system

The use of liquid crystal display button control, to meet the needs of the medical staff of different patients with the brightness of the operation.

It offers illuminance memory function.

It does not effect using when a single circuit or one bulb is broken.

4) Universal suspension system

Rotating arm, a new type of alloy material is made of eight edge type.

Balanced system using imported arm module, more than 5 group universal joints, every cantilever must has more than 3 joints which can be rotated in 360°,

The structure is light, easy to manipulate, accurate positioning, can provide the maximum range of regulation.The equipped with fatigue correcting unit and

fix position hand handle device, easy to fix position after long time use.

5) Modern laminar lamp

The thickest part of lamp-chimney is not more than 10cm.

The lamp-chimney is made of ABS, The handle on the central of lamp can be detachable, can take high temperature (≤ 134°C) sterilization treatment,

easily adjust, flexible fixed.